Schneider Electric

Schneider Electric GV4P03N6 Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4P03N6
MPN:
GV4P03N6
Condition:
New
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Fire Resistance:
960°C IEC 60695-2-11
Ip Degree Of Protection:
IP40 IEC 60529
Suitability For Isolation:
yes IEC 60947-1
Rohs Exemption Information:
Yes
Ambient Air Temperature For Operation:
-25-70°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mechanical Durability:
40000 cycles
Rated Duty:
continuous IEC 60947-4-1
Maximum Operating Rate:
25 cyc/h
Weight:
1.6 kg
Range Of Product:
TeSys GV4
Connections - Terminals:
lugs-ring terminals
Product Or Component Type:
motor circuit breaker
Device Application:
motor protection
Line Rated Current:
3.5 A
Poles Description:
3P
Height:
155 mm
Ambient Air Temperature For Storage:
-50-85°C
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Climatic Withstand:
IACS E10
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Magnetic Tripping Current:
59-59 A
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Product Name:
TeSys GV4 || TeSys Deca
Pvc Free:
Yes
Country of Origin:
Poland
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Color:
Gray RAL 7016)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Motor Power Kw:
0.55-0.55 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 500 V AC 50/60 Hz
Operating Position:
any position
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Operating Altitude:
5000 m
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Depth:
165 mm
Circularity Profile:
ENVEOLI1704004EN
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
81 mm
Environmental Disclosure:
ENVPEP1704004EN
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Warranty:
18 months
Control Type:
rotary handle
Halogen Content Performance:
Halogen free plastic parts product
$1,192.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).