Schneider Electric GV4P115N Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals
Schneider Electric
$845.00
TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Line Rated Current:
- 115 A
- Range Of Product:
- TeSys GV4
- Halogen Content Performance:
- Halogen free plastic parts product
- Power Dissipation Per Pole:
- 4.6 W
- Maximum Operating Rate:
- 25 cyc/h
- Climatic Withstand:
- IACS E10
- Eu Rohs Directive:
- Compliant with Exemptions
- Suitability For Isolation:
- yes IEC 60947-1
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Standards:
- CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
- Mechanical Durability:
- 40000 cycles
- Mechanical Robustness:
- vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
- Rated Duty:
- continuous IEC 60947-4-1
- Device Application:
- motor protection
- Breaking Capacity:
- 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
- Product Name:
- TeSys GV4 || TeSys Deca
- Device Short Name:
- GV4P
- Ambient Air Temperature For Operation:
- -25-70°C
- Trip Unit Technology:
- electronic || thermal-magnetic
- Motor Power Kw:
- 37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz IEC 60947-2
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Depth:
- 165 mm
- Weight:
- 1.6 kg
- Tightening Torque:
- 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
- Warranty:
- 18 months
- Range:
- TeSys Deca
- Net Weight:
- 1.6 kg
- Country of Origin:
- Mexico
- Mercury Free:
- Yes
- Operating Position:
- any position
- Connections - Terminals:
- EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
- Ik Degree Of Protection:
- IK07 IEC 62262
- Pvc Free:
- Yes
- [Ith] Conventional Free Air Thermal Current:
- 115 A IEC 60947-4-1
- Control Type:
- rotary handle
- [Ui] Rated Insulation Voltage:
- 800 V AC 50/60 Hz IEC 60947-2
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -50-85°C
- Ip Degree Of Protection:
- IP40 IEC 60529
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1
- Environmental Disclosure:
- ENVPEP1704004EN
- Product Or Component Type:
- motor circuit breaker
- Operating Altitude:
- 5000 m