Schneider Electric

Schneider Electric GV4P115S Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 100kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4P115S
MPN:
GV4P115S
Condition:
New
Range Of Product:
TeSys GV4
Device Application:
motor protection
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Maximum Operating Rate:
25 cyc/h
Ambient Air Temperature For Storage:
-50-85°C
Ik Degree Of Protection:
IK07 IEC 62262
Range:
TeSys Deca
Product Name:
TeSys GV4 || TeSys Deca
Phase Failure Sensitivity:
yes IEC 60947-4-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Power Dissipation Per Pole:
4.6 W
Operating Position:
any position
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 400...415 V AC 50/60 Hz || 55-55 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 55-55 kW 500 V AC 50/60 Hz || 75-75 kW 500 V AC 50/60 Hz || 75-75 kW 660...690 V AC 50/60 Hz || 90-90 kW 660...6
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Electrical Durability:
10000 cycles AC-3 440 V In/2 || 5000 cycles AC-3 440 V In
Product Or Component Type:
motor circuit breaker
Rohs Exemption Information:
Yes
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Pvc Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Environmental Disclosure:
ENVPEP1704004EN
Pollution Degree:
3
Line Rated Current:
115 A
Rated Duty:
continuous IEC 60947-4-1
Poles Description:
3P
Country of Origin:
Mexico
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Suitability For Isolation:
yes IEC 60947-1
Net Weight:
1.6 kg
Operating Altitude:
5000 m
Mechanical Durability:
40000 cycles
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Control Type:
rotary handle
Warranty:
18 months
Color:
Gray RAL 7016)
Halogen Content Performance:
Halogen free plastic parts product
Ambient Air Temperature For Operation:
-25-70°C
Circularity Profile:
ENVEOLI1704004EN
Device Short Name:
GV4P
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Magnetic Tripping Current:
1955-1955 A
$945.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose