Schneider Electric

Schneider Electric GV4P50N Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4P50N
MPN:
GV4P50N
Condition:
New
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Ip Degree Of Protection:
IP40 IEC 60529
Weight:
1.6 kg
Climatic Withstand:
IACS E10
Product Name:
TeSys GV4 || TeSys Deca
Product Or Component Type:
motor circuit breaker
Operating Altitude:
5000 m
Country of Origin:
Poland
Poles Description:
3P
Fire Resistance:
960°C IEC 60695-2-11
Magnetic Tripping Current:
850-850 A
Maximum Operating Rate:
25 cyc/h
Motor Power Kw:
11-11 kW 400...415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 660...690 V AC 50/60 Hz || 15-15 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 400...415 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 500 V AC 50/60 Hz |
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Ik Degree Of Protection:
IK07 IEC 62262
Eu Rohs Directive:
Compliant with Exemptions
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Operating Position:
any position
Control Type:
rotary handle
Height:
155 mm
Sustainable Offer Status:
Green Premium product
Halogen Content Performance:
Halogen free plastic parts product
Pvc Free:
Yes
Device Short Name:
GV4P
Suitability For Isolation:
yes IEC 60947-1
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Depth:
165 mm
Ambient Air Temperature For Operation:
-25-70°C
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Phase Failure Sensitivity:
yes IEC 60947-4-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Environmental Disclosure:
ENVPEP1704004EN
Range Of Product:
TeSys GV4
Warranty:
18 months
Ambient Air Temperature For Storage:
-50-85°C
Range:
TeSys Deca
Net Weight:
1.6 kg
Mechanical Durability:
40000 cycles
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Color:
Gray RAL 7016)
Line Rated Current:
50 A
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Circularity Profile:
ENVEOLI1704004EN
$745.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose