[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Poles Description:
3P
Product Name:
TeSys GV4 || TeSys Deca
Magnetic Tripping Current:
212-212 A
Ambient Air Temperature For Operation:
-25-70°C
Weight:
1.45 kg
Maximum Operating Rate:
25 cyc/h
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Net Weight:
1.45 kg
Rated Duty:
continuous IEC 60947-4-1
Climatic Withstand:
IACS E10
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Warranty:
18 months
Range:
TeSys Deca
Environmental Disclosure:
ENVPEP1704004EN
Range Of Product:
TeSys GV4
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Rohs Exemption Information:
Yes
Device Short Name:
GV4PE
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Suitability For Isolation:
yes IEC 60947-1
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Device Application:
motor protection
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Operating Position:
any position
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Mechanical Durability:
40000 cycles
Ip Degree Of Protection:
IP40 IEC 60529
Motor Power Kw:
3-3 kW 400...415 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz || 4-4 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 5
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Country of Origin:
Poland
Halogen Content Performance:
Halogen free plastic parts product
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Ik Degree Of Protection:
IK07 IEC 62262
Fire Resistance:
960°C IEC 60695-2-11
Depth:
116 mm
Line Rated Current:
12.5 A
Height:
155 mm
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Sustainable Offer Status:
Green Premium product
Color:
Gray RAL 7016)
Control Type:
toggle
$695.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).