Schneider Electric

Schneider Electric GV4PE50S6 Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 100kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PE50S6
MPN:
GV4PE50S6
Condition:
New
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Net Weight:
1.45 kg
Product Name:
TeSys GV4 || TeSys Deca
Halogen Content Performance:
Halogen free plastic parts product
Country of Origin:
Poland
Power Dissipation Per Pole:
4.6 W
Product Or Component Type:
motor circuit breaker
Eu Rohs Directive:
Compliant with Exemptions
Pvc Free:
Yes
Rated Duty:
continuous IEC 60947-4-1
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Ik Degree Of Protection:
IK07 IEC 62262
Height:
155 mm
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Magnetic Tripping Current:
850-850 A
Mechanical Durability:
40000 cycles
Environmental Disclosure:
ENVPEP1704004EN
Fire Resistance:
960°C IEC 60695-2-11
Warranty:
18 months
Range:
TeSys Deca
Control Type:
toggle
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Device Short Name:
GV4PE
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Range Of Product:
TeSys GV4
Device Application:
motor protection
Ip Degree Of Protection:
IP40 IEC 60529
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
lugs-ring terminals
Pollution Degree:
3
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Color:
Gray RAL 7016)
Circularity Profile:
ENVEOLI1704004EN
Climatic Withstand:
IACS E10
Depth:
116 mm
Ambient Air Temperature For Storage:
-50-85°C
Rohs Exemption Information:
Yes
Maximum Operating Rate:
25 cyc/h
Weight:
1.45 kg
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Poles Description:
3P
Operating Position:
any position
Breaking Capacity:
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 100 kA 208Y/120 V AC
Motor Power Kw:
11-11 kW 400...415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 660...690 V AC 50/60 Hz || 15-15 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 400...415 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 500 V AC 50/60 Hz |
$1,342.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose