Schneider Electric

Schneider Electric GV4PEM07N6 Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic multifunction, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PEM07N6
MPN:
GV4PEM07N6
Condition:
New
Ip Degree Of Protection:
IP40 IEC 60529
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Suitability For Isolation:
yes IEC 60947-1
Rohs Exemption Information:
Yes
Operating Altitude:
5000 m
Fire Resistance:
960°C IEC 60695-2-11
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Mercury Free:
Yes
Warranty:
18 months
Line Rated Current:
0.291666666666667
Climatic Withstand:
IACS E10
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI1704004EN
Depth:
116 mm
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Range Of Product:
TeSys GV4
Net Weight:
1.45 kg
Pollution Degree:
3
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Range:
TeSys Deca
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Power Dissipation Per Pole:
4.6 W
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Magnetic Tripping Current:
119-119 A
Product Name:
TeSys GV4 || TeSys Deca
Pvc Free:
Yes
Country of Origin:
Poland
Trip Unit Technology:
thermal-magnetic || electronic
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mechanical Durability:
40000 cycles
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Color:
Gray RAL 7016)
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connections - Terminals:
lugs-ring terminals
Device Application:
motor protection
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Motor Power Kw:
1.5-1.5 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 400...415 V AC 50/60 Hz || 2.5-2.5 kW 400...415 V AC 50/60 Hz || 3-3 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 2.5-2.5 kW 500 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500
Product Or Component Type:
motor circuit breaker
Maximum Operating Rate:
25 cyc/h
Phase Failure Sensitivity:
yes IEC 60947-4-1
$1,342.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 2.9-7A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose