Schneider Electric

Schneider Electric GV4PEM12N Motor circuit breaker, TeSys GV4, 3P, 12.5A, Icu 50kA, thermal magnetic multifunction, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PEM12N
MPN:
GV4PEM12N
Condition:
New
Color:
Gray RAL 7016)
Pvc Free:
Yes
Fire Resistance:
960°C IEC 60695-2-11
Climatic Withstand:
IACS E10
Product Name:
TeSys GV4 || TeSys Deca
Motor Power Kw:
3-3 kW 400...415 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz || 4-4 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 5
Rohs Exemption Information:
Yes
Country of Origin:
Poland
Eu Rohs Directive:
Compliant with Exemptions
Poles Description:
3P
Sustainable Offer Status:
Green Premium product
Height:
155 mm
Device Short Name:
GV4PEM
Depth:
116 mm
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Phase Failure Sensitivity:
yes IEC 60947-4-1
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Maximum Operating Rate:
25 cyc/h
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Mechanical Durability:
40000 cycles
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ik Degree Of Protection:
IK07 IEC 62262
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range Of Product:
TeSys GV4
Rated Duty:
continuous IEC 60947-4-1
Operating Altitude:
5000 m
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
motor circuit breaker
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Weight:
1.45 kg
Magnetic Tripping Current:
212-212 A
Line Rated Current:
12.5 A
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Device Application:
motor protection
Ambient Air Temperature For Operation:
-25-70°C
Trip Unit Technology:
electronic || thermal-magnetic
Warranty:
18 months
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Operating Position:
any position
Ip Degree Of Protection:
IP40 IEC 60529
Net Weight:
1.45 kg
Circularity Profile:
ENVEOLI1704004EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$1,267.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).