Schneider Electric

Schneider Electric GV4PEM50N6 Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic multifunction, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4PEM50N6
MPN:
GV4PEM50N6
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
81 mm
Control Type:
toggle
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Range Of Product:
TeSys GV4
Circularity Profile:
ENVEOLI1704004EN
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Suitability For Isolation:
yes IEC 60947-1
Climatic Withstand:
IACS E10
Warranty:
18 months
Pollution Degree:
3
Ambient Air Temperature For Operation:
-25-70°C
Line Rated Current:
50 A
Connections - Terminals:
lugs-ring terminals
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Phase Failure Sensitivity:
yes IEC 60947-4-1
Poles Description:
3P
Maximum Operating Rate:
25 cyc/h
Ip Degree Of Protection:
IP40 IEC 60529
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Range:
TeSys Deca
Rated Duty:
continuous IEC 60947-4-1
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
Halogen Content Performance:
Halogen free plastic parts product
Motor Power Kw:
11-11 kW 400...415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 660...690 V AC 50/60 Hz || 15-15 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 400...415 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 500 V AC 50/60 Hz |
Trip Unit Technology:
electronic || thermal-magnetic
Power Dissipation Per Pole:
4.6 W
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Device Short Name:
GV4PEM
Rohs Exemption Information:
Yes
Net Weight:
1.45 kg
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Depth:
116 mm
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Color:
Gray RAL 7016)
Mercury Free:
Yes
Magnetic Tripping Current:
850-850 A
Ambient Air Temperature For Storage:
-50-85°C
Fire Resistance:
960°C IEC 60695-2-11
Operating Altitude:
5000 m
Ik Degree Of Protection:
IK07 IEC 62262
Product Or Component Type:
motor circuit breaker
Mechanical Durability:
40000 cycles
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
$895.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).