Schneider Electric

Schneider Electric HL4IMA16C Surge protection device, Surgelogic, HL, 160kA, 480Y/277 VAC, 3 phase, 4 wire, SPD type 2

(No reviews yet) Write a Review
SKU:
HL4IMA16C
MPN:
HL4IMA16C
Condition:
New
Number Of Poles:
3
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Nema Degree Of Protection:
NEMA 2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Uc] Maximum Continuous Operating Voltage:
150 V
Trip Unit Technology:
thermal-magnetic
Eu Rohs Directive:
Compliant with Exemptions
Wiring Configuration:
4-wire
Standards:
UL 1449:ed. 3 || UL 1283:ed. 5 || CSA C22.2 No 8:1986 || UL 96A:ed. 12 || UL 489:ed. 11 || CSA C22.2 No 5-09
[Ue] Rated Operational Voltage:
480Y/277 V AC
Rohs Exemption Information:
Yes
Connections - Terminals:
I-Line line || lugs ground AWG 6 copper 4 N.m || lugs neutral AWG 6 copper 4 N.m
Provided Equipment:
alarm enable/disable switch || surge counter || circuit-breaker
Phase:
3 phase
Short-Circuit Protection:
200 kA
Surge Current:
160 kA
Length:
483 mm
Warranty:
18 months
Product Or Component Type:
surge protection device
Breaking Capacity:
50 kA
Breaking Capacity Code:
HL
Cable Length:
483 mm
Line Rated Current:
60 A
Mounting Support:
panel mounting
Range Of Product:
Surgelogic
Local Signaling:
status LED green per phase normal operation || status LED red per phase fault
Depth:
142.1 mm
Country of Origin:
Mexico
Device Short Name:
IMA
$11,292.00

Description

Surgelogic™ EMA and EBA series SPDs offer a full range of externally mounted surge suppression solutions. These units are designed to provide surge suppression from service entrance panels to point-of-use equipment. US and Canadian UL® Listed to the UL 1449 standard. Complies with requirements of NEC® Article 285 and CSA 22.2 No. 8- M1986 as appropriate. Complies with UL 96A 12th Edition Master Label requirements for Lightning Protection Systems. This Surelogic SPD device is a three phase, 4-wire grounded wye system that has a peak surge current rating of 160 kA. This device has operational voltage of 208Y/120 Vac and has a short circuit rating of 200 kA. This SPD is in a NEMA 2 enclosure that is 308.9 tall, 341.9 mm wide and 142.1 mm deep.
View AllClose