- Width:
- 104 mm
- Suitability For Isolation:
- yes IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Local Signalling:
- switched off (OFF) 1 trip indicator green)
- Utilisation Category:
- category A
- Depth:
- 86 mm
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Wire Stripping Length:
- 25 mm
- Ip Degree Of Protection:
- front cover IP40
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz IEC 60947-3
- Mounting Support:
- bracket
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Control Type:
- toggle
- Line Rated Current:
- 225-225 A
- Net Weight:
- 2.4 kg
- Mercury Free:
- Yes
- [Ics] Rated Service Breaking Capacity:
- 25 kA 220/240 V AC 50/60 Hz IEC 60947-2 || 18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 || 14 kA 500/525 V AC 50/60 Hz IEC 60947-2 || 20 kA 250 V DC IEC 60947-2 || 20 kA 500 V DC IEC 60947-2
- Sustainable Offer Status:
- Green Premium product
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Pollution Degree:
- 3
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Warranty:
- 18 months
- Mounting Height:
- 4.5 in
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Poles Description:
- 2P
- Environmental Disclosure:
- ENVPEP2206031EN
- Network Frequency:
- 50/60 Hz
- Protection Type:
- overload protection || short-circuit protection
- Magnetic Tripping Current:
- 2250-2250 A
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Magnetic Hold Current:
- 1125 A
- Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz UL 489 || 18 kA 480 V AC 50/60 Hz || 14 kA 600 V AC 50/60 Hz || 20 kA 250 V DC
- Communication Interface:
- Modbus
- Circularity Profile:
- ENVEOLI2206031EN
- Electrical Connection:
- I-Line connection, line || lugs, load
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Rohs Exemption Information:
- Yes
- Terminal Identifier:
- AL250JD
- Awg Gauge:
- AWG 3/0...350 kcmil aluminium/copper terminals
- Breaking Capacity Code:
- D
- Eu Rohs Directive:
- Compliant with Exemptions
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pvc Free:
- Yes
- Trip Unit Technology:
- thermal-magnetic
- Tightening Torque:
- 25-25 N.m 95-185 mm² (AWG 3/0...350 kcmil)
- Product Or Component Type:
- circuit breaker
- Continuous Current Rating:
- 0.8
- Phase Connection:
- AC
- Height:
- 191 mm
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mounting Mode:
- I-Line bracket)
- Circuit Breaker Application:
- HACR rated
- Product Certifications:
- UL || CSA || NOM
- Quality Labels:
- CE
- QN-QUOTE-REQUEST:
- true