Schneider Electric LADT03 Time delay auxiliary contact block, TeSys Deca, 1NO + 1NC, on delay 0.3-3s, front, spring terminals
Schneider Electric
$157.20
TeSys Deca time delay auxiliary contact block, for contactors LC1D and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, On-delay setting range 0.3-3s, connection by spring terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).
- Mercury Free:
- Yes
- Insulation Resistance:
- > 10 MOhm
- Color:
- dark grey
- Depth:
- 61 mm
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-5-1 || 600 V UL || 600 V CSA
- Environmental Characteristic:
- normal environment
- Country of Origin:
- France
- California Proposition 65:
- WARNING: Cancer - www.P65Warnings.ca.gov
- Sustainable Packaging:
- Yes
- Timer Type:
- on delay
- Minimum Switching Voltage:
- 17 V
- Product Or Component Type:
- time delay auxiliary contact block
- Eu Rohs Directive:
- Compliant with Exemptions
- Pole Contact Composition:
- 1 NO + 1 NC
- Non-Overlap Time:
- 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact
- Protection Type:
- gG fuse 10 A
- [Ue] Rated Operational Voltage:
- 690 V AC 25...400 Hz
- Standards:
- EN/IEC 60947-5-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN 50012 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Protective Treatment:
- TH IEC 60068
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Pvc Free:
- Yes
- Minimum Switching Current:
- 5 mA
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Product Certifications:
- CB || UL || CSA || CCC || EAC || UKCA
- Mechanical Durability:
- 5 Mcycles
- Ambient Air Temperature For Operation:
- -40-70°C
- Product Name:
- TeSys Deca
- Environmental Disclosure:
- ENVPEP110702EN_V01
- Auxiliary Contacts Operation:
- time delay
- Rohs Exemption Information:
- Yes
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Operating Altitude:
- 9842.52 ft (3000 m)
- Connections - Terminals:
- spring terminals 2 2.5-2.5 mm²flexible without cable end || spring terminals 2 2.5-2.5 mm²rigid
- Circularity Profile:
- N/A
- [Ie] Rated Operational Current:
- 6 A at 120 V AC-15 || 1.04 A at 690 V AC-15 || 0.55 A at 125 V DC-13 || 0.1 A at 600 V DC-13
- Range Compatibility:
- TeSys D CAD || TeSys D LC1D || TeSys Deca CAD || TeSys Deca LC1D
- Range:
- TeSys || TeSys Deca
- Permissible Short-Time Rating:
- 100 A 60°C 1 s || 120 A 60°C 500 ms || 140 A 60°C 100 ms
- Ip Degree Of Protection:
- IP2X conforming to IEC 60529
- Mounting Location:
- front
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C)
- Ambient Air Temperature For Storage:
- -60-80°C
- Irms Rated Making Capacity:
- 140 A AC || 250 A DC
- Sustainable Offer Status:
- Green Premium product
- Time Delay Range:
- 0.3...3 s