Schneider Electric

Schneider Electric LC1D123BL IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D123BL
MPN:
LC1D123BL
Condition:
New
Operating Altitude:
0...9842.52 ft (0...3000 m)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pollution Degree:
3
Motor Power Kw:
3 kW at 220...230 V AC 50/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 5.5 kW at 415 V AC 50/60 Hz (AC-3) || 5.5 kW at 440 V AC 50/60 Hz (AC-3) || 7.5 kW at 500 V AC 50/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 3 kW a
Product Or Component Type:
contactor
Weight:
0.485 kg
Inrush Power In W:
2.4-2.4 W 20°C)
Minimum Switching Voltage:
17 V for Signaling circuit
Maximum Horse Power Rating:
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Height:
99 mm
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Connections - Terminals:
power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable s
Country of Origin:
France
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Rohs Exemption Information:
Yes
Warranty:
18 months
Range Of Product:
TeSys Deca
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Maximum Operating Rate:
3600 cyc/h 60°C
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Flame Retardance:
V1 conforming to UL 94
Mercury Free:
Yes
Pole Contact Composition:
3 NO
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contact Composition:
1 NO + 1 NC
Net Weight:
0.485 kg
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Toxic Heavy Metal Free:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mechanical Durability:
30 Mcycles
Operating Time:
77±15 % ms closing || 25±20 % ms opening
[Ie] Rated Operational Current:
16 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Depth:
95 mm
Fire Resistance:
850°C IEC 60695-2-1
Poles Description:
3P
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 16 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant with Exemptions
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Pvc Free:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Electrical Durability:
2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
Contactor Application:
motor control || resistive load
[Uc] Control Circuit Voltage:
24 V DC
Average Impedance:
2.5 mOhm - Ith 16 A 50 Hz for power circuit
Time Constant:
40 ms
$178.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose