Schneider Electric

Schneider Electric LC1D12KUE IEC contactor, TeSys Deca Green, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D12KUE
MPN:
LC1D12KUE
Condition:
New
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || power
Ip Degree Of Protection:
IP20 front face IEC 60529
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP1609001EN
Depth:
86 mm
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Rohs Exemption Information:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Range:
TeSys || TeSys Deca
Country of Origin:
France
Overvoltage Category:
III
Coil Technology:
built-in bidirectional peak limiting
Minimum Switching Current:
5 mA for Signaling circuit
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC-3e for power circuit
Operating Time:
45...55 ms closing || 20...90 ms opening
Sustainable Offer Status:
Green Premium product
Motor Power Kw:
3 kW at 220...230 V AC 50 Hz (AC-3) || 5.5 kW at 380...400 V AC 50 Hz (AC-3) || 5.5 kW at 415 V AC 50 Hz (AC-3) || 5.5 kW at 440 V AC 50 Hz (AC-3) || 7.5 kW at 500 V AC 50 Hz (AC-3) || 7.5 kW at 660...690 V AC 50 Hz (AC-3) || 3 kW at 220...230 V AC 5
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Pole Contact Composition:
3 NO
Product Or Component Type:
contactor
Pollution Degree:
3
Width:
45 mm
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Insulation Resistance:
> 10 MOhm for Signaling circuit
Utilisation Category:
AC-1 || AC-3 || AC-3e
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
77 mm
Power Dissipation Per Pole:
1.56 W AC-1 || 0.36 W AC-3 || 0.36 W AC-3e
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Mounting Support:
rail || plate
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
0.373 kg
Inrush Power In W:
18-18 W 20°C)
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Device Short Name:
LC1D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Contactor Application:
motor control || resistive load
Mercury Free:
Yes
Flame Retardance:
V1 conforming to UL 94
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Electrical Durability:
2.3 Mcycles 11 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2.3 Mcycles 11 A AC-3e <= 440 V
Minimum Switching Voltage:
17 V for Signaling circuit
Hold-In Power Consumption In W:
1.1-1.1 W 20°C
$42.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose