Schneider Electric

Schneider Electric LC1D150G7 IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D150G7
MPN:
LC1D150G7
Condition:
New
Climatic Withstand:
IACS E10 exposure to damp heat
Pvc Free:
Yes
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Net Weight:
2.5 kg
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Maximum Operating Rate:
1200 cyc/h 60°C
Warranty:
18 months
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Rohs Exemption Information:
Yes
Heat Dissipation:
3-4.5 W at 50/60 Hz
Sustainable Packaging:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Protective Cover:
with
Protective Treatment:
THIEC 60068-2-30
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
Mechanical Durability:
8 Mcycles
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Mounting Support:
rail || plate
Overvoltage Category:
III
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Eu Rohs Directive:
Compliant with Exemptions
Operating Altitude:
0...9842.52 ft (0...3000 m)
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Device Short Name:
LC1D
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Contactor Application:
motor control || resistive load
Signaling Circuit Frequency:
25...400 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Pollution Degree:
3
Operating Time:
20...35 ms closing || 40...75 ms opening
Motor Power Kw:
40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range:
TeSys
Country of Origin:
United States
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance:
> 10 MOhm for Signaling circuit
Control Circuit Type:
AC 50/60 Hz
Product Or Component Type:
contactor
Hold-In Power Consumption In Va:
2-18 VA 60 Hz cos phi 0.9 (at 20°C) || 2-18 VA 50 Hz cos phi 0.9 (at 20°C)
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.