Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Product Certifications:
UL || CCC || CSA || CE || UKCA || Marine || EAC
Control Circuit Type:
AC 50/60 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mechanical Durability:
8 Mcycles
Fire Resistance:
850°C IEC 60695-2-1
Pvc Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Ip Degree Of Protection:
IP20 front face IEC 60529
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Weight:
2.5 kg
Country of Origin:
Czechia
Contactor Application:
motor control || resistive load
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Overvoltage Category:
III
Poles Description:
3P
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Mounting Support:
rail || plate
Hold-In Power Consumption In Va:
2-18 VA 60 Hz cos phi 0.9 (at 20°C) || 2-18 VA 50 Hz cos phi 0.9 (at 20°C)
Operating Altitude:
0...9842.52 ft (0...3000 m)
Heat Dissipation:
3-4.5 W at 50/60 Hz
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Minimum Switching Voltage:
17 V for Signaling circuit
Net Weight:
2.5 kg
Insulation Resistance:
> 10 MOhm for Signaling circuit
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP060301EN
Flame Retardance:
V1 conforming to UL 94
Minimum Switching Current:
5 mA for Signaling circuit
Pole Contact Composition:
3 NO
Operating Time:
20...35 ms closing || 40...75 ms opening
Protective Cover:
with
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Range Of Product:
TeSys Deca
Warranty:
18 months
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
[Uc] Control Circuit Voltage:
480 V AC 50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Packaging:
Yes
Protective Treatment:
THIEC 60068-2-30
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 480 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.