Schneider Electric

Schneider Electric LC1D186B7 IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D186B7
MPN:
LC1D186B7
Condition:
New
Pollution Degree:
3
Height:
77 mm
Maximum Operating Rate:
3600 cyc/h 60°C
Fire Resistance:
850°C IEC 60695-2-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Electrical Durability:
1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mounting Support:
plate || rail
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Heat Dissipation:
2-3 W at 50/60 Hz
Environmental Disclosure:
ENVPEP1501004
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 8 mm
Flame Retardance:
V1 conforming to UL 94
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Protective Treatment:
THIEC 60068-2-30
Contactor Application:
motor control || resistive load
Minimum Switching Current:
5 mA for Signaling circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Net Weight:
0.33 kg
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 8 mm M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Overvoltage Category:
III
Device Short Name:
LC1D
Pvc Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Circuit Type:
AC 50/60 Hz
[Uc] Control Circuit Voltage:
24 V AC 50/60 Hz
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP20 front face IEC 60529
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Toxic Heavy Metal Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Breaking Capacity:
300 A at 440 V for power circuit conforming to IEC 60947
Sustainable Offer Status:
Green Premium product
Poles Description:
3P
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Minimum Switching Voltage:
17 V for Signaling circuit
Weight:
0.33 kg
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Rohs Exemption Information:
Yes
Warranty:
18 months
Mercury Free:
Yes
Pole Contact Composition:
3 NO
$163.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200 to 208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose