Schneider Electric

Schneider Electric LC1D186G7 IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D186G7
MPN:
LC1D186G7
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range Of Product:
TeSys Deca
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Pvc Free:
Yes
Mechanical Durability:
15 Mcycles
Poles Description:
3P
Weight:
0.33 kg
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Protective Cover:
with
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Mounting Support:
rail || plate
Device Short Name:
LC1D
Product Certifications:
GOST || CCC || BV || CSA || UL || RINA || GL || DNV || LROS (Lloyds register of shipping) || UKCA
Net Weight:
0.33 kg
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Height:
77 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 8 mm M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3
Auxiliary Contact Composition:
1 NO + 1 NC
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Utilisation Category:
AC-1 || AC-3 || AC-4 || AC-3e
Product Or Component Type:
contactor
Control Circuit Type:
AC 50/60 Hz
Compatibility Code:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Icw] Rated Short-Time Withstand Current:
145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Power Dissipation Per Pole:
2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
Eu Rohs Directive:
Compliant
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Pollution Degree:
3
Flame Retardance:
V1 conforming to UL 94
Circularity Profile:
ENVEOLI1501004
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Heat Dissipation:
2-3 W at 50/60 Hz
Depth:
86 mm
Fire Resistance:
850°C IEC 60695-2-1
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Toxic Heavy Metal Free:
Yes
Coil Technology:
without built-in suppressor module
$163.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200 to 208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose