Schneider Electric LC1D18Q7 IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 380VAC 50/60Hz coil, open
Schneider Electric
$163.20
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 380 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Uc] Control Circuit Voltage:
- 380 V AC 50/60 Hz
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Contactor Application:
- resistive load || motor control
- [Ie] Rated Operational Current:
- 18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Sustainable Offer Status:
- Green Premium product
- Coil Technology:
- without built-in suppressor module
- Pollution Degree:
- 3
- Rated Breaking Capacity:
- 300 A at 440 V for power circuit conforming to IEC 60947
- Range Of Product:
- TeSys Deca
- [Icw] Rated Short-Time Withstand Current:
- 145 A 40°C - 10 s for power circuit || 240 A 40°C - 1 s for power circuit || 40 A 40°C - 10 min for power circuit || 84 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- Environmental Disclosure:
- ENVPEP1501004
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Protective Cover:
- with
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Pvc Free:
- Yes
- Average Impedance:
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Depth:
- 86 mm
- Electrical Durability:
- 1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Signaling Circuit Frequency:
- 25...400 Hz
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Flame Retardance:
- V1 conforming to UL 94
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Country of Origin:
- Indonesia
- Protective Treatment:
- THIEC 60068-2-30
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Fire Resistance:
- 850°C IEC 60695-2-1
- Overvoltage Category:
- III
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Product Or Component Type:
- contactor
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Toxic Heavy Metal Free:
- Yes
- Eu Rohs Directive:
- Compliant
- Maximum Horse Power Rating:
- 1 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 460/480 V AC 50/60 Hz for 3 phase mot
- Pole Contact Composition:
- 3 NO
- Power Dissipation Per Pole:
- 2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
- Mounting Support:
- rail || plate
- Mechanical Durability:
- 15 Mcycles
- Tightening Torque:
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)