
Schneider Electric LC1D18U7 IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 50/60Hz coil, open
Schneider Electric
$163.20
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Motor Power Kw:
- 4 kW at 220...230 V AC 50/60 Hz (AC-3) || 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 9 kW at 415...440 V AC 50/60 Hz (AC-3) || 10 kW at 500 V AC 50/60 Hz (AC-3) || 10 kW at 660...690 V AC 50/60 Hz (AC-3) || 4 kW at 400 V AC 50/60 Hz (AC-4) || 4 kW a
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Eu Rohs Directive:
- Compliant
- Maximum Horse Power Rating:
- 1 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 460/480 V AC 50/60 Hz for 3 phase mot
- Depth:
- 86 mm
- Compatibility Code:
- LC1D
- Sustainable Offer Status:
- Green Premium product
- Power Dissipation Per Pole:
- 2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
- Protective Cover:
- with
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Electrical Durability:
- 1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 18 A AC-3e <= 440 V
- Rated Breaking Capacity:
- 300 A at 440 V for power circuit conforming to IEC 60947
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Mercury Free:
- Yes
- Toxic Heavy Metal Free:
- Yes
- Contactor Application:
- motor control || resistive load
- Average Impedance:
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Environmental Disclosure:
- ENVPEP1501004
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Weight:
- 0.33 kg
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Coil Technology:
- without built-in suppressor module
- Range Of Product:
- TeSys Deca
- Width:
- 45 mm
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Warranty:
- 18 months
- Overvoltage Category:
- III
- Device Short Name:
- LC1D
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Control Circuit Type:
- AC 50/60 Hz
- Tightening Torque:
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- [Ie] Rated Operational Current:
- 18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Circularity Profile:
- ENVEOLI1501004
- Protective Treatment:
- THIEC 60068-2-30
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Pole Contact Composition:
- 3 NO
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold