Schneider Electric

Schneider Electric LC1D256M7 IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D256M7
MPN:
LC1D256M7
Condition:
New
Operating Altitude:
0...9842.52 ft (0...3000 m)
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contact Composition:
1 NO + 1 NC
Coil Technology:
without built-in suppressor module
Net Weight:
0.37 kg
Mechanical Durability:
15 Mcycles
Rohs Exemption Information:
Yes
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
Operating Time:
12...22 ms closing || 4...19 ms opening
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 25 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Contactor Application:
motor control || resistive load
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Utilisation Category:
AC-1 || AC-3 || AC-3e
Range Of Product:
TeSys Deca
Depth:
92 mm
Control Circuit Type:
AC 50/60 Hz
Minimum Switching Voltage:
17 V for Signaling circuit
Motor Power Kw:
5.5 kW at 220...230 V AC 50/60 Hz || 11 kW at 380...400 V AC 50/60 Hz || 11 kW at 415...440 V AC 50/60 Hz || 15 kW at 500 V AC 50/60 Hz || 15 kW at 660...690 V AC 50/60 Hz
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI110229EN
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Flame Retardance:
V1 conforming to UL 94
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Compatibility Code:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Width:
45 mm
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
220 V AC 50/60 Hz
Country of Origin:
United States
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Poles Description:
3P
Product Or Component Type:
contactor
Signaling Circuit Frequency:
25...400 Hz
Mounting Support:
rail || plate
Protective Cover:
with
Environmental Disclosure:
ENVPEP110229EN
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Ip Degree Of Protection:
IP20 front face IEC 60529
Eu Rohs Directive:
Compliant
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$181.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose