Schneider Electric

Schneider Electric LC1D32LE7 IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D32LE7
MPN:
LC1D32LE7
Condition:
New
Mechanical Durability:
15 Mcycles
Motor Power Kw:
7.5 kW at 220...230 V AC 50/60 Hz (AC-3) || 15 kW at 380...400 V AC 50/60 Hz (AC-3) || 15 kW at 415...440 V AC 50/60 Hz (AC-3) || 18.5 kW at 500 V AC 50/60 Hz (AC-3) || 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 7.5 kW at 400 V AC 50/60 Hz (AC-4) |
Auxiliary Contact Composition:
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
[Uc] Control Circuit Voltage:
208 V AC 50/60 Hz
Control Circuit Type:
AC 50/60 Hz
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Circularity Profile:
ENVEOLI110229EN
Minimum Switching Voltage:
17 V for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Width:
45 mm
Pvc Free:
Yes
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
[Icw] Rated Short-Time Withstand Current:
260 A 40°C - 10 s for power circuit || 430 A 40°C - 1 s for power circuit || 60 A 40°C - 10 min for power circuit || 138 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Depth:
92 mm
Overvoltage Category:
III
Range Of Product:
TeSys Deca
Minimum Switching Current:
5 mA for Signaling circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Product Or Component Type:
contactor
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Protective Treatment:
THIEC 60068-2-30
Warranty:
18 months
Electrical Durability:
1.65 Mcycles 32 A AC-3 <= 440 V || 1.4 Mcycles 50 A AC-1 <= 440 V || 1.65 Mcycles 32 A AC-3e <= 440 V
Operating Time:
12...22 ms closing || 4...19 ms opening
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Environmental Disclosure:
ENVPEP110229EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Product Certifications:
UL || RINA || CCC || LROS (Lloyds register of shipping) || DNV || GL || GOST || CSA || BV || UKCA
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Sustainable Offer Status:
Green Premium product
Heat Dissipation:
2-3 W at 50/60 Hz
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Mounting Support:
plate || rail
Eu Rohs Directive:
Compliant
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Coil Technology:
without built-in suppressor module
Rohs Exemption Information:
Yes
Power Dissipation Per Pole:
2 W AC-3 || 5 W AC-1 || 2 W AC-3e
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Compatibility Code:
LC1D
Insulation Resistance:
> 10 MOhm for Signaling circuit
$206.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 208 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.83 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose