Schneider Electric

Schneider Electric LC1D40A6BNE IEC contactor, TeSys Deca Green, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 24/60VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A6BNE
MPN:
LC1D40A6BNE
Condition:
New
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Product Or Component Type:
contactor
Halogen Content Performance:
Halogen free plastic parts & cables product
Connections - Terminals:
power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Environmental Disclosure:
ENVPEP1607010EN
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Weight:
0.992 kg
Maximum Operating Rate:
3600 cyc/h 60°C
Compatibility Code:
LC1D
Pole Contact Composition:
3 NO
Range:
TeSys || TeSys Deca
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Mounting Support:
plate || rail
Hold-In Power Consumption In W:
0.7-0.7 W 20°C
Minimum Switching Current:
5 mA for Signaling circuit
Overvoltage Category:
III
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Electrical Durability:
2 Mcycles 35 A AC-3 <= 440 V || 0.7 Mcycles 60 A AC-1 <= 440 V || 2 Mcycles 35 A AC-3e <= 440 V
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Net Weight:
0.992 kg
Operating Time:
55...65 ms closing || 20...80 ms opening
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Ip Degree Of Protection:
IP20 front face IEC 60529
Auxiliary Contact Composition:
1 NO + 1 NC
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Inrush Power In Va:
15-15 VA 50/60 Hz (at 20°C)
Poles Description:
3P
Rohs Exemption Information:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Contactor Application:
resistive load || motor control
Motor Power Kw:
11 kW at 220...230 V AC 50 Hz (AC-3) || 18.5 kW at 380...400 V AC 50 Hz (AC-3) || 22 kW at 415 V AC 50 Hz (AC-3) || 22 kW at 440 V AC 50 Hz (AC-3) || 22 kW at 500 V AC 50 Hz (AC-3) || 30 kW at 660...690 V AC 50 Hz (AC-3) || 11 kW at 220...230 V AC 50
[Uc] Control Circuit Voltage:
24...60 V AC 50/60 Hz || 24...60 V DC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Coil Technology:
built-in bidirectional peak limiting
Range Of Product:
TeSys Deca
Flame Retardance:
V1 conforming to UL 94
Mechanical Durability:
6 Mcycles
Inrush Power In W:
16-16 W 20°C)
$330.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.