Schneider Electric

Schneider Electric LC1D40A6LE7 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 208VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A6LE7
MPN:
LC1D40A6LE7
Condition:
New
Heat Dissipation:
4-5 W at 60 Hz
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 16.5 mm
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || control circuit 1.7 N.m screw clamp terminals pozidriv No
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Ip Degree Of Protection:
IP20 front face IEC 60529
Poles Description:
3P
Depth:
120 mm
Coil Technology:
without built-in suppressor module
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Environmental Disclosure:
ENVPEP1503009EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
Signaling Circuit Frequency:
25...400 Hz
Mounting Support:
plate || rail
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Compatibility Code:
LC1D
Reach Free Of Svhc:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Protective Cover:
with
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Country of Origin:
France
Sustainable Packaging:
Yes
Overvoltage Category:
III
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Maximum Operating Rate:
3600 cyc/h 60°C
Fire Resistance:
850°C IEC 60695-2-1
Pole Contact Composition:
3 NO
Operating Time:
4...19 ms opening || 12...26 ms closing
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Product Or Component Type:
contactor
Minimum Switching Voltage:
17 V for Signaling circuit
Toxic Heavy Metal Free:
Yes
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Weight:
0.85 kg
Pvc Free:
Yes
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C)
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Range:
TeSys || TeSys Deca
Maximum Horse Power Rating:
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
Auxiliary Contact Composition:
1 NO + 1 NC
Protective Treatment:
THIEC 60068-2-30
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Contactor Application:
motor control || resistive load
$327.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 208 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose