Schneider Electric

Schneider Electric LC1D40AB6 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40AB6
MPN:
LC1D40AB6
Condition:
New
Device Short Name:
LC1D
Toxic Heavy Metal Free:
Yes
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Height:
122 mm
Heat Dissipation:
4-5 W at 60 Hz
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Compatibility Code:
LC1D
Range:
TeSys || TeSys Deca
Pvc Free:
Yes
Eu Rohs Directive:
Compliant
Circularity Profile:
ENVEOLI1503009EN
Fire Resistance:
850°C IEC 60695-2-1
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Pollution Degree:
3
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 60 Hz
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Minimum Switching Current:
5 mA for Signaling circuit
Country of Origin:
France
Reach Free Of Svhc:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Maximum Operating Rate:
3600 cyc/h 60°C
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 18.
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Width:
55 mm
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Control Circuit Type:
AC 60 Hz
Utilisation Category:
AC-1 || AC-3 || AC-4 || AC-3e
Operating Altitude:
0...9842.52 ft (0...3000 m)
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C)
Coil Technology:
without built-in suppressor module
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || Signaling circuit 690 V IEC 60947-1
Depth:
120 mm
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Mercury Free:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Product Or Component Type:
contactor
Mounting Support:
plate || rail
Maximum Horse Power Rating:
3 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase m
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
[Uc] Control Circuit Voltage:
24 V AC 60 Hz
Net Weight:
0.85 kg
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
$261.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.