Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Electrical Durability:
0.7 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Minimum Switching Voltage:
17 V for Signaling circuit
Time Constant:
34 ms
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Country of Origin:
France
Control Circuit Type:
DC standard
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Auxiliary Contact Composition:
1 NO + 1 NC
Height:
122 mm
Sustainable Offer Status:
Green Premium product
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Contactor Application:
resistive load || motor control
Fire Resistance:
850°C IEC 60695-2-1
Depth:
120 mm
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Inrush Power In W:
19-19 W 20°C)
Eu Rohs Directive:
Compliant
Reach Free Of Svhc:
Yes
Compatibility Code:
LC1D
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Protective Cover:
with
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame Retardance:
V1 conforming to UL 94
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Pvc Free:
Yes
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Signaling Circuit Frequency:
25...400 Hz
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Rohs Exemption Information:
Yes
Protective Treatment:
THIEC 60068-2-30
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
Environmental Disclosure:
ENVPEP1503009EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Uc] Control Circuit Voltage:
24 V DC
Device Short Name:
LC1D
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Net Weight:
0.925 kg
$275.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.