Schneider Electric

Schneider Electric LC1D50AP7 IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 230VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50AP7
MPN:
LC1D50AP7
Condition:
New
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Weight:
0.855 kg
Maximum Operating Rate:
3600 cyc/h 60°C
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Environmental Disclosure:
ENVPEP1503009EN
Minimum Switching Voltage:
17 V for Signaling circuit
Height:
122 mm
Range Of Product:
TeSys Deca
Range:
TeSys || TeSys Deca
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mechanical Durability:
6 Mcycles
Pvc Free:
Yes
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Flame Retardance:
V1 conforming to UL 94
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Fire Resistance:
850°C IEC 60695-2-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Mercury Free:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Compatibility Code:
LC1D
Coil Technology:
without built-in suppressor module
Country of Origin:
Indonesia
Reach Free Of Svhc:
Yes
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant
Heat Dissipation:
4-5 W at 50/60 Hz
Net Weight:
0.855 kg
Overvoltage Category:
III
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Minimum Switching Current:
5 mA for Signaling circuit
Motor Power Kw:
15 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 380...400 V AC 50/60 Hz (AC-3) || 30 kW at 500 V AC 50/60 Hz (AC-3) || 33 kW at 660...690 V AC 50/60 Hz (AC-3) || 25 kW at 415 V AC 50/60 Hz (AC-3) || 30 kW at 440 V AC 50/60 Hz (AC-3) || 11 kW at 4
Circularity Profile:
ENVEOLI1503009EN
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contact Composition:
1 NO + 1 NC
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Depth:
120 mm
Pole Contact Composition:
3 NO
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Signaling Circuit Frequency:
25...400 Hz
Warranty:
18 months
Ip Degree Of Protection:
IP20 front face IEC 60529
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Operating Time:
4...19 ms opening || 12...26 ms closing
Device Short Name:
LC1D
$295.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose