Schneider Electric

Schneider Electric LC1D50F7 IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50F7
MPN:
LC1D50F7
Condition:
New
Auxiliary Contact Composition:
1 NO + 1 NC
Width:
85 mm
Fire Resistance:
850°C IEC 60695-2-1
Inrush Power In Va:
160-160 VA cos phi 0.75 (at 20°C)
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.75...1.25 Uc -40-60°C operational DC || 0.1...0.3 Uc -40-70°C drop-out DC
Reach Free Of Svhc:
Yes
Product Certifications:
GL || LROS (Lloyds register of shipping) || RINA || CCC || BV || DNV || GOST || CSA || UKCA
Minimum Switching Current:
5 mA for control circuit
Utilisation Category:
AC-1 || AC-4 || AC-3 || AC-3e
Environmental Disclosure:
ENVPEP110205EN
Associated Fuse Rating:
100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 || 10 A gG for control circuit conforming to IEC 60947-5-1
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mechanical Robustness:
shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
Sustainable Offer Status:
Green Premium product
Insulation Resistance:
> 10 MOhm for control circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Standards:
CSA C22.2 No 14 || IEC 60947-4-1 || IEC 60947-5-1 || EN 60947-5-1 || EN 60947-4-1
Eu Rohs Directive:
Compliant
Compatibility Code:
LC1D
Non-Overlap Time:
1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
Safety Reliability Level:
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 || B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Hold-In Power Consumption In Va:
15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Contactor Application:
resistive load || motor control
Pvc Free:
Yes
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Mounting Support:
rail
Control Circuit Type:
DC standard
Flame Retardance:
V1 conforming to UL 94
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Rohs Exemption Information:
Yes
Depth:
176 mm
[Ui] Rated Insulation Voltage:
control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL IEC 60947-1 || control circuit 690 V IEC 60947-1 || power circuit 690 V CSA IEC 60947-1 || control circuit 600 V CSA
Net Weight:
2.185 kg
[Uc] Control Circuit Voltage:
110 V DC
Weight:
2.185 kg
Range:
TeSys
Warranty:
18 months
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947 || 250 A DC for control circuit conforming to IEC 60947-5-1
Minimum Switching Voltage:
17 V for control circuit
Country of Origin:
France
Pole Contact Composition:
3 NO
Connections - Terminals:
control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cab
Product Or Component Type:
contactor
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mercury Free:
Yes
$388.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose