Schneider Electric LC1D65AG7 IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open
Schneider Electric
$386.40
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Warranty:
- 18 months
- Heat Dissipation:
- 4-5 W at 60 Hz
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz
- Maximum Horse Power Rating:
- 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 5 hp at 115 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 20 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 20 hp at 230/240 V AC 50/60 Hz for 3 phase
- Width:
- 55 mm
- Product Or Component Type:
- contactor
- Environmental Disclosure:
- ENVPEP1503009EN
- Power Dissipation Per Pole:
- 9.6 W AC-1 || 6.3 W AC-3 || 6.3 W AC-3e
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Poles Description:
- 3P
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C)
- Pole Contact Composition:
- 3 NO
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Range Of Product:
- TeSys Deca
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Rohs Exemption Information:
- Yes
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Coil Technology:
- without built-in suppressor module
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Tightening Torque:
- control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
- Range:
- TeSys || TeSys Deca
- Depth:
- 120 mm
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Country of Origin:
- France
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Toxic Heavy Metal Free:
- Yes
- Pollution Degree:
- 3
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Device Short Name:
- LC1D
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Protective Cover:
- with
- Sustainable Offer Status:
- Green Premium product
- Contactor Application:
- motor control || resistive load
- Eu Rohs Directive:
- Compliant
- Signaling Circuit Frequency:
- 25...400 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Mercury Free:
- Yes
- Utilisation Category:
- AC-4 || AC-1 || AC-3 || AC-3e
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 60 Hz