Schneider Electric

Schneider Electric LC1D65M7 IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D65M7
MPN:
LC1D65M7
Condition:
New
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive:
Compliant
Auxiliary Contacts Type:
mirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Non-Overlap Time:
1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
Associated Fuse Rating:
125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 10 A gG for control circuit conformi
Weight:
1.4 kg
Device Short Name:
LC1D
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Mercury Free:
Yes
Irms Rated Making Capacity:
140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 || 140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Minimum Switching Current:
5 mA for control circuit
Control Circuit Voltage Limits:
0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz
Mechanical Durability:
6000000 cycles
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Product Certifications:
DNV || LROS (Lloyds register of shipping) || CCC || CSA || BV || UL || GL || GOST || UKCA || RINA
Environmental Disclosure:
ENVPEP110205EN
Country of Origin:
Czechia
Mechanical Robustness:
shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
Auxiliary Contact Composition:
1 NO + 1 NC
Rohs Exemption Information:
Yes
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-4-1
Height:
127 mm
Motor Power Kw:
30 kW at 380...400 V AC 50 Hz || 37 kW at 500 V AC 50 Hz || 37 kW at 660...690 V AC 50 Hz || 18.5 kW at 220...230 V AC 50 Hz || 30 kW at 415 V AC 50 Hz || 37 kW at 1000 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50
Compatibility Code:
LC1D
Safety Reliability Level:
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 || B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Reach Free Of Svhc:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Fire Resistance:
850°C IEC 60695-2-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Warranty:
18 months
[Ui] Rated Insulation Voltage:
control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL IEC 60947-1 || control circuit 690 V IEC 60947-1 || power circuit 690 V CSA IEC 60947-1 || control circuit 600 V CSA
Width:
75 mm
Operating Altitude:
0...9842.52 ft (0...3000 m)
Circularity Profile:
N/A
Utilisation Category:
AC-1 || AC-2 || AC-4 || AC-3e
Mounting Support:
plate
Pole Contact Composition:
3 NO
Connections - Terminals:
control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: rigid without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cab
[Ie] Rated Operational Current:
65 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Insulation Resistance:
> 10 MOhm for control circuit
Overvoltage Category:
III
Inrush Power In Va:
160-160 VA cos phi 0.75 (at 20°C) || 140-140 VA cos phi 0.75 (at 20°C)
Pvc Free:
Yes
Net Weight:
1.4 kg
Operating Time:
12...26 ms closing || 4...19 ms opening
Toxic Heavy Metal Free:
Yes
Maximum Horse Power Rating:
10 hp at 230/240 V AC 60 Hz for 1 phase motors || 20 hp at 200/208 V AC 60 Hz for 3 phase motors || 20 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 50 hp at 575/600 V AC 60 Hz for 3 phase motors ||
$532.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.