Schneider Electric

Schneider Electric LC1D80GD IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D80GD
MPN:
LC1D80GD
Condition:
New
Auxiliary Contact Composition:
1 NO + 1 NC
Maximum Horse Power Rating:
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 30 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 60 hp at 460/480 V AC 50/60 Hz for 3 phas
Mechanical Durability:
4 Mcycles
Width:
85 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range:
TeSys
Ip Degree Of Protection:
IP20 front face IEC 60529
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.85...1.1 Uc -40-55°C operational DC || 1...1.1 Uc 55-70°C operational DC
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Weight:
2.59 kg
[Uc] Control Circuit Voltage:
125 V DC
Control Circuit Type:
DC standard
Hold-In Power Consumption In W:
22-22 W 20°C
Minimum Switching Voltage:
17 V for Signaling circuit
Pvc Free:
Yes
Operating Time:
95...130 ms closing || 20...35 ms opening
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Packaging:
Yes
Overvoltage Category:
III
Protective Treatment:
THIEC 60068-2-30
Circularity Profile:
N/A
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || shocks contactor open 8 Gn for 11 ms) || vibrations contactor closed 3 Gn, 5...300 Hz) || shocks contactor closed 10 Gn for 11 ms)
Compatibility Code:
LC1D
Flame Retardance:
V1 conforming to UL 94
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Power Dissipation Per Pole:
5.1 W AC-3 || 12.5 W AC-1 || 5.1 W AC-3e
Signaling Circuit Frequency:
25...400 Hz
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ue] Rated Operational Voltage:
power circuit <= 300 V DC 25...400 Hz || power circuit <= 690 V AC
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Depth:
186 mm
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Warranty:
18 months
Protective Cover:
with
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Inrush Power In W:
22-22 W 20°C)
Pole Contact Composition:
3 NO
$447.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.32 inches deep. It weighs 5.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose