Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Mechanical Durability:
30 Mcycles
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Product Or Component Type:
contactor
Weight:
0.365 kg
Power Dissipation Per Pole:
1.56 W AC-1
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Control Circuit Type:
DC standard
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Overvoltage Category:
III
Flame Retardance:
V1 conforming to UL 94
Contactor Application:
resistive load
Width:
45 mm
Warranty:
18 months
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Sustainable Offer Status:
Green Premium product
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit
Range Of Product:
TeSys Deca
Operating Time:
20±20 % ms opening || 63±15 % ms closing
Operating Altitude:
0...9842.52 ft (0...3000 m)
Inrush Power In W:
5.4-5.4 W 20°C)
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
Time Constant:
28 ms
Mercury Free:
Yes
Poles Description:
4P
Circularity Profile:
ENVEOLI1102030EN
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 20 A (at 60°C) for power circuit
Utilisation Category:
AC-1
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Pollution Degree:
3
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Depth:
99 mm
Eu Rohs Directive:
Compliant with Exemptions
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Pole Contact Composition:
4 NO
Ip Degree Of Protection:
IP20 front face IEC 60529
Rohs Exemption Information:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Range:
TeSys || TeSys Deca
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Average Impedance:
2.5 mOhm - Ith 20 A 50 Hz for power circuit
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Pvc Free:
Yes
$133.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 20A resistive load rating. Contactor is supplied with a 125 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.