Schneider Electric

Schneider Electric LC1DT25BL IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT25BL
MPN:
LC1DT25BL
Condition:
New
Warranty:
18 months
Country of Origin:
France
Overvoltage Category:
III
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Height:
85 mm
Minimum Switching Current:
5 mA for Signaling circuit
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Mounting Support:
rail || plate
Protective Cover:
with
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Range Of Product:
TeSys Deca
Weight:
0.365 kg
Ip Degree Of Protection:
IP20 front face IEC 60529
Compatibility Code:
LC1D
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Time Constant:
40 ms
Mechanical Durability:
30 Mcycles
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Width:
45 mm
Operating Altitude:
0...9842.52 ft (0...3000 m)
Contactor Application:
resistive load
Device Short Name:
LC1D
Control Circuit Type:
DC low consumption
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
Mercury Free:
Yes
Pvc Free:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Inrush Power In W:
2.4-2.4 W 20°C)
Range:
TeSys || TeSys Deca
[Uc] Control Circuit Voltage:
24 V DC
Circularity Profile:
ENVEOLI1102030EN
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Electrical Durability:
0.8 Mcycles 25 A AC-1 <= 440 V
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
contactor
Minimum Switching Voltage:
17 V for Signaling circuit
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Protective Treatment:
THIEC 60068-2-30
Auxiliary Contact Composition:
1 NO + 1 NC
Pole Contact Composition:
4 NO
Maximum Operating Rate:
3600 cyc/h 60°C
Sustainable Offer Status:
Green Premium product
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
$199.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose