Schneider Electric

Schneider Electric LC1DT25LE7 IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, 208VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT25LE7
MPN:
LC1DT25LE7
Condition:
New
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
without built-in suppressor module
Weight:
0.365 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mercury Free:
Yes
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power Dissipation Per Pole:
1.56 W AC-1
Product Or Component Type:
contactor
Compatibility Code:
LC1D
Minimum Switching Current:
5 mA for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Fire Resistance:
850°C IEC 60695-2-1
Maximum Operating Rate:
3600 cyc/h 60°C
Net Weight:
0.365 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Depth:
92 mm
Mechanical Durability:
15 Mcycles
Sustainable Offer Status:
Green Premium product
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Environmental Disclosure:
ENVPEP1501004
Auxiliary Contact Composition:
1 NO + 1 NC
[Uc] Control Circuit Voltage:
208 V AC 50/60 Hz
Product Certifications:
DNV || BV || GOST || RINA || LROS (Lloyds register of shipping) || CSA || CCC || UL || GL
Operating Time:
4...19 ms opening || 12...22 ms closing
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Pole Contact Composition:
4 NO
Range Of Product:
TeSys Deca
Toxic Heavy Metal Free:
Yes
Mounting Support:
rail || plate
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Country of Origin:
Singapore
Contactor Application:
resistive load
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Range:
TeSys || TeSys Deca
Operating Altitude:
0...9842.52 ft (0...3000 m)
Poles Description:
4P
Overvoltage Category:
III
$159.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 208 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose