Schneider Electric

Schneider Electric LC1DT25MD IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, 220VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT25MD
MPN:
LC1DT25MD
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
0.365 kg
Auxiliary Contact Composition:
1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Flame Retardance:
V1 conforming to UL 94
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 250 A at 440 V for power circuit conforming to IEC 60947
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Protective Cover:
with
Product Or Component Type:
contactor
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Electrical Durability:
0.8 Mcycles 25 A AC-1 <= 440 V
Maximum Operating Rate:
3600 cyc/h 60°C
Operating Altitude:
0...9842.52 ft (0...3000 m)
Ip Degree Of Protection:
IP20 front face IEC 60529
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Sustainable Offer Status:
Green Premium product
Device Short Name:
LC1D
Minimum Switching Voltage:
17 V for Signaling circuit
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Time Constant:
28 ms
Fire Resistance:
850°C IEC 60695-2-1
Weight:
0.365 kg
[Uc] Control Circuit Voltage:
220 V DC
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Mechanical Durability:
30 Mcycles
Poles Description:
4P
[Icw] Rated Short-Time Withstand Current:
30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Protective Treatment:
THIEC 60068-2-30
Pole Contact Composition:
4 NO
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Control Circuit Type:
DC standard
Range:
TeSys || TeSys Deca
Hold-In Power Consumption In W:
5.4-5.4 W 20°C
Power Dissipation Per Pole:
1.56 W AC-1
Control Circuit Voltage Limits:
0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Pollution Degree:
3
Contactor Application:
resistive load
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Warranty:
18 months
Operating Time:
20±20 % ms opening || 63±15 % ms closing
Country of Origin:
Indonesia
$166.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 220 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose