Schneider Electric

Schneider Electric LC1DT60A6BNE IEC contactor, TeSys Deca Green, nonreversing, 60A resistive, 4 pole, 4 NO, 24/60VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT60A6BNE
MPN:
LC1DT60A6BNE
Condition:
New
Pole Contact Composition:
4 NO
Connections - Terminals:
power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Compatibility Code:
LC1D
Device Short Name:
LC1D
Contactor Application:
resistive load
Height:
122 mm
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Rohs Exemption Information:
Yes
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Poles Description:
4P
Operating Altitude:
0...9842.52 ft (0...3000 m)
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Operating Time:
55...65 ms closing || 20...80 ms opening
Average Impedance:
1.6 mOhm - Ith 60 A 50 Hz for power circuit
Coil Technology:
built-in bidirectional peak limiting
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC-1 for power circuit
Flame Retardance:
V1 conforming to UL 94
Product Or Component Type:
contactor
Weight:
1.230 kg
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Range Of Product:
TeSys Deca
Maximum Operating Rate:
3600 cyc/h 60°C
Pollution Degree:
3
Environmental Disclosure:
ENVPEP1607010EN
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Mounting Support:
plate || rail
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Range:
TeSys || TeSys Deca
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Fire Resistance:
850°C IEC 60695-2-1
Electrical Durability:
0.7 Mcycles 60 A AC-1 <= 440 V
[Uc] Control Circuit Voltage:
24...60 V AC 50/60 Hz || 24...60 V DC
Overvoltage Category:
III
Ip Degree Of Protection:
IP20 front face IEC 60529
Inrush Power In W:
16-16 W 20°C)
Hold-In Power Consumption In W:
0.7-0.7 W 20°C
Net Weight:
1.230 kg
Halogen Content Performance:
Halogen free plastic parts & cables product
Minimum Switching Voltage:
17 V for Signaling circuit
Warranty:
18 months
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Hold-In Power Consumption In Va:
1-1 VA 50/60 Hz (at 20°C)
$445.20

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 60A resistive load rating. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.40 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose