Schneider Electric

Schneider Electric LC1DT80A3E7 IEC contactor, TeSys D, nonreversing, 80A resistive, 4 pole, 4 NO, 48VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1DT80A3E7
MPN:
LC1DT80A3E7
Condition:
New
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Compatibility Code:
LC1D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Pole Contact Composition:
4 NO
Flame Retardance:
V1 conforming to UL 94
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Environmental Disclosure:
ENVPEP1503009EN
Utilisation Category:
AC-1
Mercury Free:
Yes
Range Of Product:
TeSys Deca
Tightening Torque:
power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 2.5-25 mm² hexagonal 4 mm
Overvoltage Category:
III
Eu Rohs Directive:
Compliant
Pollution Degree:
3
Sustainable Offer Status:
Green Premium product
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Protective Cover:
with
Width:
70 mm
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Operating Time:
4...19 ms opening || 12...26 ms closing
Net Weight:
1.15 kg
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Height:
122 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Warranty:
18 months
Power Dissipation Per Pole:
10.2 W AC-1
Average Impedance:
1.6 mOhm - Ith 80 A 50 Hz for power circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Rohs Exemption Information:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Mounting Support:
plate || rail
Pvc Free:
Yes
Mechanical Durability:
6 Mcycles
Device Short Name:
LC1D
Minimum Switching Current:
5 mA for Signaling circuit
Contactor Application:
resistive load
Electrical Durability:
1.4 Mcycles 80 A AC-1 <= 440 V
Product Or Component Type:
contactor
Auxiliary Contact Composition:
1 NO + 1 NC
Heat Dissipation:
4-5 W at 50/60 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Control Circuit Type:
AC 50/60 Hz
Fire Resistance:
850°C IEC 60695-2-1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$450.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose