[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Average Impedance:
1.6 mOhm - Ith 80 A 50 Hz for power circuit
Pollution Degree:
3
Control Circuit Type:
AC 50/60 Hz
Toxic Heavy Metal Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Electrical Durability:
1.4 Mcycles 80 A AC-1 <= 440 V
Product Certifications:
UL || CCC || GOST || GL || DNV || RINA || LROS (Lloyds register of shipping) || CSA || BV
Environmental Disclosure:
ENVPEP1503009EN
Mounting Support:
rail || plate
Overvoltage Category:
III
Eu Rohs Directive:
Compliant
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Signaling Circuit Frequency:
25...400 Hz
Minimum Switching Voltage:
17 V for Signaling circuit
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Protective Treatment:
THIEC 60068-2-30
Pvc Free:
Yes
Power Dissipation Per Pole:
10.2 W AC-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Device Short Name:
LC1D
Utilisation Category:
AC-1
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
without built-in suppressor module
Fire Resistance:
850°C IEC 60695-2-1
Minimum Switching Current:
5 mA for Signaling circuit
Height:
122 mm
Heat Dissipation:
4-5 W at 50/60 Hz
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Auxiliary Contact Composition:
1 NO + 1 NC
Reach Free Of Svhc:
Yes
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Circularity Profile:
ENVEOLI1503009EN
Maximum Operating Rate:
3600 cyc/h 60°C
Product Or Component Type:
contactor
Insulation Resistance:
> 10 MOhm for Signaling circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Pole Contact Composition:
4 NO
Depth:
120 mm
Rohs Exemption Information:
Yes
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m screw clamp terminals 25-35 mm² hexagonal 4 mm || power circuit 5 N.m screw clamp terminals 1-25 mm² hex
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1000 A at 440 V for power circuit conforming to IEC 60947
Compatibility Code:
LC1D
Range:
TeSys || TeSys Deca
Width:
70 mm
Flame Retardance:
V1 conforming to UL 94
$540.96

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 80A resistive load rating. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.76 inches wide and 4.72 inches deep. It weighs 2.54 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.