Schneider Electric

Schneider Electric LC1K090087Y7 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 660 to 690VAC coil

(No reviews yet) Write a Review
SKU:
LC1K090087Y7
MPN:
LC1K090087Y7
Condition:
New
Signaling Circuit Frequency:
<= 400 Hz
Toxic Heavy Metal Free:
Yes
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Sustainable Offer Status:
Green Premium product
Control Circuit Type:
AC 50/60 Hz
Poles Description:
4P
Weight:
0.18 kg
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Country of Origin:
France
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Product Or Component Type:
contactor
Ip Degree Of Protection:
IP2X VDE 0106
Rohs Exemption Information:
Yes
Overvoltage Category:
III
Contactor Application:
resistive load
Mounting Support:
rail || plate
Eu Rohs Directive:
Compliant
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Depth:
57 mm
Mercury Free:
Yes
Inrush Power In Va:
30-30 VA (at 20°C)
Mechanical Durability:
10 Mcycles
Pole Contact Composition:
2 NO + 2 NC
Utilisation Category:
AC-1
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Connections - Terminals:
Faston terminals 2 2.8 mm) || Faston terminals 1 6.35 mm)
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Circularity Profile:
ENVEOLI1503003EN
[Uc] Control Circuit Voltage:
660...690 V AC 50/60 Hz
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Reach Free Of Svhc:
Yes
Heat Dissipation:
1.3-1.3 W
Environmental Disclosure:
ENVPEP1503003EN
Net Weight:
0.18 kg
Maximum Operating Rate:
3600 cyc/h
$81.00