Schneider Electric

Schneider Electric LC1K0901D7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 42VAC coil

(No reviews yet) Write a Review
SKU:
LC1K0901D7
MPN:
LC1K0901D7
Condition:
New
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Rohs Exemption Information:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mercury Free:
Yes
Range:
TeSys
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Auxiliary Contact Composition:
1 NC
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Mounting Support:
plate || rail
Pole Contact Composition:
3 NO
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Current:
5 mA for Signaling circuit
Maximum Operating Rate:
3600 cyc/h
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Width:
45 mm
Auxiliary Contacts Type:
instantaneous 1 NC
Device Application:
control
Inrush Power In Va:
30-30 VA (at 20°C)
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Eu Rohs Directive:
Compliant
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Depth:
57 mm
Contactor Application:
motor control || resistive load
Circularity Profile:
ENVEOLI1503003EN
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Control Circuit Type:
AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Non Overlap Distance:
0.5 mm
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
Overvoltage Category:
III
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Toxic Heavy Metal Free:
Yes
Mechanical Durability:
10 Mcycles
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Device Short Name:
LC1K
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Weight:
0.18 kg
Ip Degree Of Protection:
IP2X VDE 0106
Signaling Circuit Frequency:
<= 400 Hz
$75.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 42V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose