- Reach Free Of Svhc:
- Yes
- Contactor Application:
- motor control || resistive load
- Utilisation Category:
- AC-3 || AC-3e || AC-1 || AC-4
- Maximum Operating Rate:
- 3600 cyc/h
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Rohs Exemption Information:
- Yes
- Device Application:
- control
- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
- Range:
- TeSys
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Device Short Name:
- LC1K
- Electrical Durability:
- 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Net Weight:
- 0.18 kg
- Country of Origin:
- United States
- Weight:
- 0.18 kg
- Ip Degree Of Protection:
- IP2X VDE 0106
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Environmental Disclosure:
- ENVPEP1503003EN
- Warranty:
- 18 months
- Circularity Profile:
- ENVEOLI1503003EN
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Eu Rohs Directive:
- Compliant
- Auxiliary Contact Composition:
- 1 NC
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Signaling Circuit Frequency:
- <= 400 Hz
- Pole Contact Composition:
- 3 NO
- Non Overlap Distance:
- 0.5 mm
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Toxic Heavy Metal Free:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Uc] Control Circuit Voltage:
- 120 V AC 50/60 Hz
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Product Or Component Type:
- contactor
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Poles Description:
- 3P
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.20 Uc (at <50°C)
- Control Circuit Type:
- AC 50/60 Hz
- Auxiliary Contacts Type:
- instantaneous 1 NC
- Mounting Support:
- plate || rail