Schneider Electric

Schneider Electric LC1K12105B7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO aux., 24VAC coil

(No reviews yet) Write a Review
SKU:
LC1K12105B7
MPN:
LC1K12105B7
Condition:
New
Overvoltage Category:
III
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Auxiliary Contacts Type:
instantaneous 1 NO
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Storage:
-50-80°C
Operating Altitude:
6561.68 ft (2000 m) without derating
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Insulation Resistance:
> 10 MOhm for Signaling circuit
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Range:
TeSys
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Width:
45 mm
Device Application:
control
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Poles Description:
3P
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Mercury Free:
Yes
Warranty:
18 months
Depth:
57 mm
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Circularity Profile:
ENVEOLI1503003EN
Toxic Heavy Metal Free:
Yes
Contactor Application:
resistive load || motor control
Auxiliary Contact Composition:
1 NO
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Maximum Operating Rate:
3600 cyc/h
Country of Origin:
France
Mounting Support:
printed circuit boards
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Pole Contact Composition:
3 NO
Non Overlap Distance:
0.5 mm
Sustainable Packaging:
Yes
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Product Or Component Type:
contactor
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Environmental Disclosure:
ENVPEP1503003EN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Weight:
0.18 kg
Inrush Power In Va:
30-30 VA (at 20°C)
Reach Free Of Svhc:
Yes
Irms Rated Making Capacity:
144 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Rohs Exemption Information:
Yes
Net Weight:
0.18 kg
Connections - Terminals:
solder pins 0.035 mm)
$86.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by solder pins for printed circuit boards. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose