Schneider Electric

Schneider Electric LC2D115F7 REVERSING CONTACTOR 575VAC 115A IEC

(No reviews yet) Write a Review
SKU:
LC2D115F7
MPN:
LC2D115F7
Condition:
New
Insulation Resistance:
> 10 MOhm for Signaling circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Utilisation Category:
AC-1 || AC-3 || AC-3e
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open6 Gn for 11 ms
Minimum Switching Voltage:
17 V for Signaling circuit
Mechanical Durability:
8000000 cycles
Overvoltage Category:
III
Interlocking Type:
electrical || mechanical
Ambient Air Temperature For Storage:
-60-80°C
Weight:
6.35 kg
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Hold-In Power Consumption In Va:
2-18 VA 20°C) 0.3 60 Hz || 2-18 VA 20°C) 0.3 50 Hz
Pole Contact Composition:
3 NO
Range:
TeSys
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Pollution Degree:
3
Flame Retardance:
V1 conforming to UL 94
Power Dissipation Per Pole:
24 W AC-1 || 7.9 W AC-3 || 7.9 W AC-3e
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Time:
20...50 ms closing || 6...20 ms opening
Eu Rohs Directive:
Compliant with Exemptions
Coil Technology:
built-in bidirectional peak limiting diode suppressor
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Presentation:
preassembled with reversing power busbar
Electrical Durability:
0.8 Mcycles 200 A AC-1 <= 440 V || 0.95 Mcycles 115 A AC-3 <= 440 V || 0.95 Mcycles 115 A AC-3e <= 440 V
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Fire Resistance:
850°C IEC 60695-2-1
Country of Origin:
France
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Maximum Horse Power Rating:
30 hp at 200/208 V AC 60 Hz for 3 phase motors || 40 hp at 230/240 V AC 60 Hz for 3 phase motors || 75 hp at 460/480 V AC 60 Hz for 3 phase motors || 100 hp at 575/600 V AC 60 Hz for 3 phase motors
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
[Icw] Rated Short-Time Withstand Current:
250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
Rohs Exemption Information:
Yes
Signaling Circuit Frequency:
25...400 Hz
Control Circuit Voltage Limits:
0.3...0.5 Uc 55-55°C drop-out AC 50/60 Hz || 0.8...1.15 Uc 55-55°C operational AC 50/60 Hz
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Climatic Withstand:
IACS E10
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Device Short Name:
LC2D
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Pvc Free:
Yes
$1,465.80

Description

LC2D115F7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 115A AC-3 55kW@400V, it includes a 110V 50/60Hz AC coil, 2NO+2NC aux contacts, mechanical and electrical interlock. LC2D115F7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 55kW@400V. It includes a 110V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical and electrical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 266mm wide, for DIN-rail and panel mounting. Assembled with mechanical and electrical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 110V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 0.9 million cycles at 115A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.