Maximum Horse Power Rating:
40 hp at 200/208 V AC 60 Hz for 3 phase motors || 50 hp at 230/240 V AC 60 Hz for 3 phase motors || 100 hp at 460/480 V AC 60 Hz for 3 phase motors || 125 hp at 575/600 V AC 60 Hz for 3 phase motors
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Insulation Resistance:
> 10 MOhm for Signaling circuit
Environmental Disclosure:
ENVPEP060301EN
Warranty:
18 months
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Pole Contact Composition:
3 NO
Ambient Air Temperature For Storage:
-60-80°C
Net Weight:
6.4 kg
Control Circuit Type:
AC 50/60 Hz
Protective Cover:
with
Device Short Name:
LC2D
Depth:
148 mm
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Poles Description:
3P
Ip Degree Of Protection:
IP20 front face IEC 60529
Product Or Component Type:
reversing contactor
Connections - Terminals:
control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible without cable end || control circu
Protective Treatment:
TH IEC 60068-2-30
Mounting Support:
rail || plate
Auxiliary Contact Composition:
1 NO + 1 NC
Electrical Durability:
0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Sustainable Offer Status:
Green Premium product
Height:
158 mm
Product Certifications:
BV || CCC || CSA || DNV || GL || RINA || UL || EAC || UKCA
Motor Power Kw:
40 kW at 220...230 V AC 50 Hz || 75 kW at 380...400 V AC 50 Hz || 80 kW at 415...440 V AC 50 Hz || 90 kW at 500 V AC 50 Hz || 100 kW at 660...690 V AC 50 Hz || 75 kW at 1000 V AC 50 Hz
Maximum Operating Rate:
1200 cyc/h 60°C
Mechanical Durability:
8000000 cycles
Eu Rohs Directive:
Compliant with Exemptions
Device Presentation:
preassembled with reversing power busbar
Width:
266 mm
Climatic Withstand:
IACS E10
Pvc Free:
Yes
Heat Dissipation:
3-4.5 W 50/60 Hz
Inrush Power In Va:
280-350 VA 60 Hz 0.9 20°C) || 280-350 VA 50 Hz 0.9 20°C)
Ambient Air Temperature For Operation:
-40-60°C || 60-70°C with derating
Mercury Free:
Yes
Pollution Degree:
3
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Power Dissipation Per Pole:
24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
Hold-In Power Consumption In Va:
2-18 VA 20°C) 0.9 60 Hz || 2-18 VA 20°C) 0.9 50 Hz
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
[Icw] Rated Short-Time Withstand Current:
250 A 40°C - 10 min for power circuit || 580 A 40°C - 1 min for power circuit || 1200 A 40°C - 10 s for power circuit || 1400 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 m
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
Flame Retardance:
V1 conforming to UL 94
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Circularity Profile:
ENVEOLI100405EN
Coil Technology:
built-in bidirectional peak limiting diode suppressor
$1,700.00

Description

LC2D150G7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 150A AC-3 75kW@400V, it includes a 120V 50/60Hz AC coil, 2NO+2NC aux contacts, mechanical and electrical interlock. LC2D150G7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 75kW@400V. It includes a 120V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical and electrical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 266mm wide, for DIN-rail and panel mounting. Assembled with mechanical and electrical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 120V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 0.8 million cycles at 150A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.