- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Contactor Application:
- motor control || resistive load
- Protective Cover:
- with
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Circularity Profile:
- ENVEOLI1102030EN
- Connections - Terminals:
- control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit scr
- Product Name:
- TeSys Deca
- Range:
- TeSys || TeSys Deca
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor closed15 Gn for 11 ms || shocks contactor open8 Gn for 11 ms
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Pvc Free:
- Yes
- Motor Power Kw:
- 9 kW at 220...230 V AC 50-60 Hz || 18.5 kW at 380...400 V AC 50-60 Hz || 18.5 kW at 415 V AC 50-60 Hz || 18.5 kW at 440 V AC 50-60 Hz || 18.5 kW at 500 V AC 50-60 Hz || 18.5 kW at 660...690 V AC 50-60 Hz
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Utilisation Category:
- AC-3 || AC-1 || AC-3e
- Maximum Horse Power Rating:
- 5 hp at 240 V AC 60 Hz for 1 phase motors
- Operating Time:
- 53.55...72.45 ms closing || 16...24 ms opening
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
- Warranty:
- 18 months
- Weight:
- 1.137 kg
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Flame Retardance:
- V1 conforming to UL 94
- Control Circuit Type:
- DC standard
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
- Sustainable Offer Status:
- Green Premium product
- Net Weight:
- 1.137 kg
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Country of Origin:
- France
- Overvoltage Category:
- III
- Pollution Degree:
- 3
- Environmental Disclosure:
- ENVPEP110230EN
- Device Short Name:
- LC2D
- Poles Description:
- 3P
- Mercury Free:
- Yes
- Power Dissipation Per Pole:
- 5 W AC-1 || 3 W AC-3 || 3 W AC-3e
- Device Presentation:
- preassembled with reversing power busbar
- Mechanical Durability:
- 30 Mcycles
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -60-80°C
- Width:
- 90 mm
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact