control circuit 1 1-4 mm²flexible with cable end || power circuit 2 1-25 mm²flexible with cable end || power circuit 2 1-25 mm²flexible without cable end || power circuit 2 1-25 mm²solid without cable end || power circuit 2 1-35 mm²flexible with
Eu Rohs Directive:
Compliant
Reach Free Of Svhc:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Warranty:
18 months
Tightening Torque:
control circuit 1.7 N.m 1-2.5 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-2.5 mm² Philips No 2 || control circuit 1.7 N.m 1-4 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-4 mm² Philips No 2 || power circuit 5 N.m 1-25 mm² hexagonal || power c
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Shock Resistance:
10 gn contactor closed || 8 gn contactor opened
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Fire Resistance:
850°C IEC 60695-2-1
Assembly Style:
ready assembled
Motor Power Kw:
11 kW 220...240 V AC 50/60 Hz || 22 kW 415 V AC 50/60 Hz || 22 kW 440 V AC 50/60 Hz || 22 kW 500 V AC 50/60 Hz || 30 kW 660...690 V AC 50/60 Hz || 18.5 kW 380...400 V AC 50/60 Hz
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Sustainable Offer Status:
Green Premium product
Mounting Support:
rail || plate
Standards:
CSA C22.2 No 14 || IEC 60947-4-1 || EN 60947-4-1 || UL 508 || IEC 60947-5-1 || EN 60947-5-1
Range Of Product:
TeSys Deca
Circularity Profile:
N/A
Interlocking Type:
mechanical
Control Circuit Voltage Limits:
drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60°C) || operational: 0.8...1.1 Uc at 50 Hz (at <60°C) || operational: 0.85...1.1 Uc at 60 Hz (at <60°C)
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Pro-active China RoHS declaration (out of China RoHS legal scope)
Protective Cover:
with
Operating Altitude:
9842.52 ft (3000 m) without derating
Overvoltage Category:
III
Toxic Heavy Metal Free:
Yes
Contactor Application:
motor control
Hold-In Power Consumption In Va:
20-20 VA 50 Hz cos phi 0.3 (at 20°C) || 22-22 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C) || 26-26 VA 60 Hz cos phi 0.3 (at 20°C)
LC2D115M7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 115A AC-3 55kW@400V, it includes a 220V 50/60Hz AC coil, 2NO+2NC aux contacts, mechanical and...
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 40A/590V AC-3 (18.5kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC...
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in...
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in...
TeSys D reversing contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides low consumption 100-250V AC/DC coils with electronic control, 2NO+2NC built-in...
TeSys D replacement AC coil 440V 50/60Hz for TeSys D contactors. To be used with 3 and 4-pole contactors LC1 D40 to D95. It operates in the voltage limits 0.85-1.1 Uc and environments until 55°C...