Schneider Electric

Schneider Electric LC2D80E7 TeSys Deca reversing contactor - 3P(3 NO) - AC-3/AC-3e - <= 440 V 80 A - 48 V AC coil

(No reviews yet) Write a Review
SKU:
LC2D80E7
MPN:
LC2D80E7
Condition:
New
Product Certifications:
UL || CSA || RINA || GOST || CCC || DNV || LROS (Lloyds register of shipping) || GL || BV || UKCA
Auxiliary Contact Composition:
1 NO + 1 NC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Device Presentation:
preassembled with reversing power busbar
Maximum Operating Rate:
3600 cyc/h 60°C
Height:
127 mm
Country of Origin:
Czechia
Signaling Circuit Frequency:
25...400 Hz
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Power Dissipation Per Pole:
12.5 W AC-1 || 5.1 W AC-3 || 5.1 W AC-3e
Warranty:
18 months
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1100 A at 440 V for power circuit conforming to IEC 60947
Electrical Durability:
0.8 Mcycles 125 A AC-1 <= 440 V || 1.5 Mcycles 80 A AC-3 <= 440 V || 1.5 Mcycles 80 A AC-3e <= 440 V
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Minimum Switching Voltage:
17 V for Signaling circuit
Depth:
158 mm
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 125 A (at 60°C) for power circuit
Product Name:
TeSys Deca
Operating Time:
20...35 ms closing || 6...20 ms opening
Reach Free Of Svhc:
Yes
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.
Interlocking Type:
mechanical
[Ie] Rated Operational Current:
125 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 55 A (at <60°C) at <= 400 V AC AC-4 for power circuit
Heat Dissipation:
6-10 W 50/60 Hz
Inrush Power In Va:
245-245 VA 60 Hz cos phi 0.75 (at 20°C) || 245-245 VA 50 Hz cos phi 0.75 (at 20°C)
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || shocks contactor open8 Gn for 11 ms || vibrations contactor closed3 Gn, 5...300 Hz || shocks contactor closed10 Gn for 11 ms
Average Impedance:
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Coil Technology:
without built-in suppressor module
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-55°C operational AC 50 Hz || 0.85...1.1 Uc -40-55°C operational AC 60 Hz || 1...1.1 Uc 55-70°C operational AC 50/60 Hz
Hold-In Power Consumption In Va:
26-26 VA 60 Hz cos phi 0.3 (at 20°C) || 26-26 VA 50 Hz cos phi 0.3 (at 20°C)
Maximum Horse Power Rating:
20 hp at 200/208 V AC 60 Hz for 3 phase motors || 7.5 hp at 115 V AC 60 Hz for 1 phase motors || 15 hp at 230/240 V AC 60 Hz for 1 phase motors || 25 hp at 230/240 V AC 60 Hz for 3 phase motors || 60 hp at 460/480 V AC 60 Hz for 3 phase motors || 60
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Fire Resistance:
850°C IEC 60695-2-1
Motor Power Kw:
22 kW at 220...230 V AC 50 Hz || 37 kW at 380...400 V AC 50 Hz || 45 kW at 415...440 V AC 50 Hz || 55 kW at 500 V AC 50 Hz || 45 kW at 660...690 V AC 50 Hz
Protective Cover:
with
Climatic Withstand:
IACS E10
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Flame Retardance:
V1 conforming to UL 94
Minimum Switching Current:
5 mA for Signaling circuit
Connections - Terminals:
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit s
Range:
TeSys
$925.70

Description

LC2D80E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 80A AC-3 37kW@400V, it includes a 48V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D80E7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 37kW@400V. It includes a 48V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 182mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 48V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.2 million cycles at 80A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.
View AllClose