Schneider Electric

Schneider Electric LC2K1201G7 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NC, 120VAC coil

(No reviews yet) Write a Review
SKU:
LC2K1201G7
MPN:
LC2K1201G7
Condition:
New
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit || 12 A at <= 440 V AC AC-3 for power circuit || 12 A at <= 440 V AC AC-3e for power circuit
Reach Free Of Svhc:
Yes
Country of Origin:
France
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Contactor Application:
resistive load || motor control
Heat Dissipation:
1.3-1.3 W
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Poles Description:
3P
Circularity Profile:
ENVEOLI1503003EN
Ambient Air Temperature For Operation:
-25-50°C
Non Overlap Distance:
0.5 mm
Mercury Free:
Yes
Height:
58 mm
Overvoltage Category:
III
Mounting Support:
plate || rail
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Pole Contact Composition:
3 NO
Electrical Durability:
1.3 Mcycles 12 A AC-3 <= 440 V || 1.3 Mcycles 12 A AC-3e <= 440 V || 0.3 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 72 A AC-4 <= 440 V
Ip Degree Of Protection:
IP20 VDE 0106
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Minimum Switching Voltage:
17 V for Signaling circuit
Environmental Disclosure:
ENVPEP1503003EN
Warranty:
18 months
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Net Weight:
0.39 kg
Device Presentation:
preassembled with reversing power busbar
Irms Rated Making Capacity:
144 A at 690 V AC for power circuit conforming to NF C 63-110 || 144 A at 690 V AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Mechanical Durability:
5 Mcycles
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Inrush Power In Va:
30-30 VA (at 20°C)
Product Name:
TeSys K
Toxic Heavy Metal Free:
Yes
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 80 A - 1 s for Sign
Interlocking Type:
mechanical
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Signaling Circuit Frequency:
<= 400 Hz
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Product Or Component Type:
reversing contactor
Range:
TeSys
$191.00

Description

LC2K1201G7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 120V 50/60Hz AC coil, 2NC auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K1201G7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 120V 50/60Hz AC coil and 2NC built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 120V AC coil compatible 50/60Hz and 2NC built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
View AllClose