Schneider Electric

Schneider Electric LP1K0901BD3 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 9A, 1 NC aux, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP1K0901BD3
MPN:
LP1K0901BD3
Condition:
New
Height:
58 mm
Weight:
0.225 kg
Environmental Disclosure:
ENVPEP1503003EN
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Maximum Operating Rate:
3600 cyc/h
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Inrush Power In W:
3-3 W 20°C)
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Control Circuit Type:
DC standard
Device Short Name:
LP1K
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Contactor Application:
motor control || resistive load
Overvoltage Category:
III
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Ip Degree Of Protection:
IP2X
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Ambient Air Temperature For Storage:
-50-80°C
Depth:
57 mm
Range:
TeSys
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Auxiliary Contact Composition:
1 NC
Minimum Switching Current:
5 mA for Signaling circuit
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Ambient Air Temperature For Operation:
-25-50°C
Eu Rohs Directive:
Compliant
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Minimum Switching Voltage:
17 V for Signaling circuit
Auxiliary Contacts Type:
instantaneous 1 NC
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Uc] Control Circuit Voltage:
24 V DC
Heat Dissipation:
1.3-1.3 W
Net Weight:
0.225 kg
Warranty:
18 months
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Circularity Profile:
ENVEOLI1503003EN
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Operating Altitude:
6561.68 ft (2000 m) without derating
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
$102.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with transient suppressor module, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose