Schneider Electric

Schneider Electric LX1G4RKUEN Control module,TeSys Giga,100-250V AC/DC,for LC1G265-330/4P standard version

(No reviews yet) Write a Review
SKU:
LX1G4RKUEN
MPN:
LX1G4RKUEN
Condition:
New
Inrush Power In Va:
840-840 VA 240 V AC, 60 Hz
Range Compatibility:
TeSys G LX1G contactor coil
Operating Time:
20...35 ms opening || 40...55 ms closing
Ambient Air Temperature For Operation:
-25-60°C
Standards:
EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
Circularity Profile:
ENVEOLI2105013
Hold-In Power Consumption In W:
5.9-5.9 W DC
Eu Rohs Directive:
Compliant with Exemptions
Operating Altitude:
9842.52 ft (3000 m) without derating || 5000 m with derating factor
Product Or Component Type:
contactor coil
Mechanical Durability:
5 Mcycles
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
IP20 IEC 60529
Range:
TeSys
Connections - Terminals:
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2
Rohs Exemption Information:
Yes
[Uc] Control Circuit Voltage:
100...250 V AC/DC 50/60 Hz
Depth:
93.0 mm
Coil Technology:
built-in bidirectional peak limiting
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Device Short Name:
LX1G
Inrush Power In W:
645.0 W DC
Hold-In Power Consumption In Va:
10.6-10.6 VA 240 V AC, 60 Hz
Environmental Disclosure:
ENVPEP2105013
Electromagnetic Compatibility:
EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity tes
Mercury Free:
Yes
China Rohs Regulation:
X
Pollution Degree:
3 IEC 60947-1
Country of Origin:
China
Ambient Air Temperature For Storage:
-60-80°C
Control Circuit Voltage Limits:
operational 0.8...1.1 Uc 60°C) || drop-out 0...0.45 Uc 60°C)
Maximum Operating Rate:
600 cyc/mn 60°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
4P
Product Compatibility:
LC1G265...330
Quantity Per Set:
1
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
$240.00

Description

It is a 100-250V AC/DC control module for 4 poles TeSys Giga 265-300 contactor (standard version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit, pole status and diagnostic signaling circuits. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.
View AllClose